Enmet Corporation
Request More Info
email info@enmet.com
Enmet Home Enmet Products Enmet Support and Documentation Enmet Corporate Info
Enmet
Spectrum Series Spectrum SP
Enmet

You are Here: Home » Personal Single Gas Monitors » Formaldemeter

Navigate this page:

carrot

Specifications

carrot

Accessories

carrot

Contact ENMET

carrot

Download Printable Version for this Instrument

carrot

Go To Product Literature

Enmet spacer
 
gas selector
 
Enmet spacer
Detection Range:
0.05 - 10ppm Formaldehyde
Enmet spacer
 
Enmet spacer

Calibration Equipment, Replacement Parts and Accessories are available. Call us for More Information.

Enmet spacer

Formaldemeter htV
Portable Direct Reading Formaldehyde Monitor

  • Easy to use - minimal training required

  • Rapid response time

  • Real time readings allow immediate response to results

  • Reliable electrochemical sensor

  • Does not require inconvenient ancillary sampling equipment or readers

  • Simple in-field calibration

  • Small, hand-held instrument

  • Light-weight

  • Optional Base Unit for continuous monitoring

 

The Formaldemeter htV offers a simple way to monitor levels of airborne formaldehyde in the environment. The instrument is easy to use with a simple four-button keypad and features an easy-to-read four-digit display. It employs a well-proven electrochemical formaldehyde sensor that will provide an immediate indication of formaldehyde levels. Unlike other formaldehyde monitoring devices, such as, color stain tubes and badges, the Formaldemeter htV is capable of measuring many samples consecutively without the need for inconvenient ancillary equipment. Real-time results also mean that potential overexposures can be identified as they occur, without the delay and expense associated with laboratory analysis.

 

Also available, the Glutaraldmeter 3, for glutaraldehyde monitoring.


Enmet spacer

Specifications

sensor Sensor: Electrochemical
Calibration Calibration: In-field formaldehyde calibration standard
display Display: 4-digit LCD
sampling frequency Sampling Frequency: Typically once every 3 to 5

    minutes depending on previous reading
sample volume Sample Volume: Approx. 10 ml
detection range Detection Range: 0.05-10 ppm (optional high

    range: 80 ppm)
precision Precision: 10% at 2 ppm level
response time Response Time: <10 seconds
temperature Temperature: By key interrogation, displayed in degrees C
humidity Humidity: By key interrogation, displayed in % rH
power Power: 9 volt alkaline battery
enclosure Enclosure: ABS plastic
weight Weight: Instrument: 10 ounces (310g)

    Complete Kit: 1.75 lbs. (795g)
dimensions Dimensions: Instrument: 6 x 3.25 x 1.25 inches

    (150 x 80 x 32 mm)
    Carrying Case: 10.5 x 8.5 x 2 inches

    (265 x 215 x 50 mm)

spacer

Applications

Formaldehyde is a common contaminant found in new construction, residential housing and commercial buildings following renovation. It is used in many products, industries and other types of activities, including:

 

Textile treatment
Medical labs
Laminated boards
Pharmaceuticals
Synthetic resins
Horticulture
Paints
Mortuaries

Paper products
Biological
Dye stuffs
Particle boards
Commercial buildings
Cosmetics
Residential construction
Hospitals

 

 

back to top

 

spacer

Cross Sensitivity Chart

Compound
Acetone
Acetaldehyde
Acetic acid
Ammonia
Butanol
Carbon monoxide
Ethylene
Ethanol
Formaldehyde
Glutaraldehyde
Methanol
Phenol
Propanol
Resorcinol

ppm to = 1 ppm reading
No Response
8-12
No Response
71000
Note (2)
100
160
12-20
1.0
7100 at 25° C, Note (3)
50
5, Note (1)
Note (2)
5, Note (1)



Notes:

(1) Completely removed with filter provided
(2) Interference above 60° C nd 20 ppm
(3) Monitor with Glutaraldmeter 3

back to top

Enmet spacer

Accessories and Replacment Parts

Instrument Kit

Phenol Filters (supplied with instrument kit)
These filters can be used, when necesssary, for the removal of phenol and resorcinol.

 

Calibration Standard (supplied with instrument kit)
The calibration standard is a tube which produces a known concentration of formaldehyde vapor for testing and, if necessary, adjusting the accuracy of the monitor. The standard has a 100-sample capacity or a useful life of six months, whichever occurs sooner.

 

Options

AMS-2 Base Unit
The Base Unit automates operation of the Formaldemeter htV for semi-continuous sampling. Monitoring of all three parameters (formaldehyde, temperature, and humidity) is possible with the AMS-2, giving real-time data and alarm (TWA/STEL) levels. A built-in printer provides a record of the results. All data is stored and can be downloaded to a PC via RS-232 and available download software.

 

AMS-2/htV Download Software
Data logged into the AMS-2 can be viewed on the LCD and outputted to the integral printer. If required, the data can be downloaded to most PC based spreadsheets using the AMS-2/htV Download Software.

 

Ordering Information

Part No.
02700-100

Description
Instrument Kit, with Formaldemeter htV, 10 phenol filters, thermometer, pen, calibration standard, instruction manual and case.

02710-000 Instrument Kit, with Glutaraldmeter 3, 10 phenol filters, thermometer, pen, calibration standard, instruction manual and case.
02700-251 Optional data logging station, Model AMS-2 Base Unit for htV
02700-256 Optional PC download software for AMS-2/htV
02700-001 Formaldehyde Calibration Standard, typical life 6 to 12 months
02710-001 Glutaraldehyde Calibration Standard, typical life 6 to 12 months
02700-002 Replacement Phenol Filters, pack of 10
02700-003 Replacement Formaldehyde Sensor, typical life 3-4 years

back to top

Enmet
Ask Us a Question GSA Contract GS-24F-3035G, GS-24F-0001K
GSA Contract GS-24F-3035G, GS-24F-0001K

Home | Products: Overview | Stationary Fixed Continuous Monitors | Portable Multigas Monitors

Personal Single Gas Monitors | Respiratory Compressed Air Monitors

Support & Documentation: Overview | Technical Information | Instrument Manuals

Corporate Info: Contact Info | Company Profile | Safety Seminars

 

P.O. Box 979, Ann Arbor, Michigan 48106-0979   Phone (734) 761-1270, FAX (734) 761-3220

© 2006-2007 Enmet Corporation. All Rights Reserved. (ah)

Developed by Miller Media Inc.