HAZMATCAD Plus™
Hazardous Material Chemical Agent Detector
HAZMATCAD Plus™ is a multifunction handheld instrument that detects and classifies chemical warfare agents, Nerve (G) and Blister (H), with an integral electrochemical sensor array for Toxic Industrial Chemicals (TIC). When compared to other chemical agent multi threat technologies HAZMATCAD Plus™ is designed to be reliable, fast to start up, easy to operate and avoid false alarms from non-target chemicals in the urban environment. The HAZMATCAD Plus™ offers two modes of operation, one for fast response and general operation and one for high sensitivity, lowering the sensitivity threshold by approximately 10 times the fast response level.
- Compact, lightweight, handheld
- Fast warm up
- Nerve, blister & select TIC detection
- Dual mode operation
- Fast mode
- High sensitivity mode
- Requires no calibration
- Bump test accessory
Weight: 1.43Kg or 50 oz (including batteries)
Dimensions: 5.8×20.0×24.9 cm or 2.3×7.9×9.8 inches
Warm up: <3 Minutes
CW Agents: Detected VX, GA, GB, GD, HD, HN3, AC, CG, Halogens and Hydrides
Alarm Levels Nerve:
- Fast Mode: 0.3 to 0.9 mg/m3 or 0.04 to 0.14 ppm
- High Sensitivity Mode: 0.06 to 0.18 mg/m3 or 0.01 to 0.03 ppm
Alarm Levels Blister:
- Fast Mode: 1.4 mg/m3 or 0.2 ppm
- High Sensitivity Mode: 0.28 mg/m to 0.04 ppm
Alarm Level Toxic Industrial Chemicals:
- Hydrogen Cyanide (AC) 5.0ppm
- Phosgene (CG) 0.3ppm
- Halogens 10.0ppm
- Hydrides 0.5ppm
Battery Type: Li Ion
Mission Life:
- Fast Mode: 8 hours
- High Sensitivity Mode: 12 hours
Audible Alarm: 85dB at 0.1 m
Operating Temperature: 0° to 40°C or 32° to 105°F
Operating Humidity: 0-95% non-condensing atmosphere
Warranty: 1 year parts and labor
Nerve Agents:
- GA (Tabun)
- GB (Sarin)
- GD (Soman)
- GF
- VX
- HN3 (Nitrogen Mustard)
- HD (Sulfur Mustard)
- AC (Hydrogen Cyanide)
- CG (Phosgene)
Halogens and Hydrides
To place an order, please contact our experienced and professional customer service team:
PHONE: 270-745-0099
EMAIL: [email protected]
If you cannot find what you need or require a custom part, simply call and speak to one of our knowledgeable gas monitoring experts. They will be able to walk you through the ordering process quickly and professionally.
Description Part No.
HAZMATCAD Plus™ Series™ – M1001060
Detects Nerve, Blister and Select
Toxic Industrial Chemicals