Available for % LEL Combustible Gases, or ppm levels of CO, H2S, Hydrocarbons, Organic Solvents and other Toxic Gases. The AM-5150 features a rugged, long-life metal oxide semiconductor (MOS) sensor. The sensor is available either in a separate junction box for remote mounting up to several hundred feet from the monitor, or as an integral component attached to the instrument.
- User-programmable alarms and high capacity relays
- 4-20 mA inputs
- 100-240 VAC, 12 VDC power options
- High-integrity polycarbonate enclosure
- RS-485 digital communication capability
- Available with remote or optional integral sensor
Display: 8 Character, high contrast dot matrix LCD with backlight
Alarm Levels: Three, user adjustable
Audible Alarm: 105 dB at 30 cm (12 inches), factory set to activate at Alarm 1, user adjustable
Visual Gas Alarm: 3 Red LEDs
Visual Power/Fault: Green/Red LED
Temp. Range: 32° to 122°F (0° to 50°C)
Outputs: Relays: 4 Form C, 10A SPDT contacts, 3 gas alarms and 1 fault
Analog: 4-20 mA
Digital: RS-485 Modbus
Power: 100-240 VAC and/or 24 VDC, 15W. Supplied with strain relief for 0.20 to 0.35 inch diameter power cable
Enclosure: Polycarbonate
Size, Instrument Only: 7 x 5 x 3 inches (18 x 13 x 8 cm)
Weight: 2 lbs. (0.9 kg)
- Acetone (CH3)2CO
- Butane (C4H10)
- 2-Butanone (MEK) (C4H80)
- Carbon monoxide (CO)
- Combustible Gas
- Cyclohexanol (CH2)5CHOH
- Ethyl alcohol (C2H5OH)
- Ethylene (C2H4)
- Ethylene oxide (ETO) (C2H4O)
- Freon-134
- Gasoline
- Heptane (C7H16)
- Hexane (C6H14)
- Hydrocarbons
- Hydrogen (H2)
- Hydrogen sulfide( H2S)
- Isobutane (C4H10)
- Isobutylene (C4H8)
- Isopropanol (CH3) CHOH
- Isopropyl alcohol (IPA) (C3H8O)
- Kerosene
- Methane (CH4)
- Methanol (CH3OH)
- Methyl alcohol (CH3OH)
- Methyl chloride (CH3Cl)
- Methyl ethyl ketone (MEK) (C4H8O)
- Methylene chloride (CH2Cl2)
- Natural Gas
- Organic solvents
- Pentane (C5H12)
- Propane (C3H8)
- Solvents
- Toluene (C7H8)
- Trichloroethylene (C2HCl3)
- Volatile Organic Compounds (VOCs)
- Xylene (C8H10)
Options:
The sensor is available either in separate junction box for remote mounting, or as an integral component attached to the instrument. Please specify how you would like sensor supplied when ordering the instrument.
Calibration Equipment for AM-5150:
Part No. Description
03700-001 Calibration Regulator & Humidifier Assembly
03219-XXX Calibration Gas, 34 liter steel cylinder, Carbon monoxide, CO
03220-XXX Calibration Gas, 34 liter steel cylinder, Methane, CH4
03221-XXX Calibration Gas, 34 liter steel cylinder, Propane, C3H8
03227-XXX Calibration Gas, 34 liter steel cylinder, Hydrogen, H2
03281-XXX Calibration Gas, 34 liter steel cylinder, Methyl chloride, CH3Cl
03282-XXX Calibration Gas, 34 liter steel cylinder, Butane, C4H10
03296-209 Zero Gas, 34 liter steel cylinder, 20.9% Oxygen, O2
73083-000 Carrying Case, holds up to two Calibration Gas Cylinders
To place an order, please contact our experienced and professional customer service team:
PHONE: 734-761-1270
EMAIL: [email protected]
If you cannot find what you need or require a custom part, simply call and speak to one of our knowledgeable gas monitoring experts. They will be able to walk you through the ordering process quickly and professionally.
Instrument Part No.
AM-5150 Monitor with remote HV sensor 10040-008
AM-5150 Monitor with integral HV sensor 10040-018