EX-5120 Infrared Hydrocarbon Sensor
Remote Gas Monitoring Sensor Transmitter with Infrared Sensor for Hydrocarbons
EX-5120 remote gas monitoring sensor transmitter incorporates a sensor that operates on the NDIR principle to monitor the concentration of hydrocarbon gas. It can be calibrated for a specific gas, such as methane, but also responds to some other hydrocarbon gases, including propane, butane, etc. The sensor features an integral semiconductor for temperature compensation, a durable tungsten filament IR light source, filter and a dual temperature-compensated pyroelectric infrared detector. This sensor transmitter can operate in anaerobic atmospheres and in continuous hydrocarbon environments. This unit provides long-term stability and requires minimal maintenance.
The EX-5120 sensor transmitter operates on 24 VDC power and features three LED alarm point indicators, 4-20 mA output and optional alarm relay board. This sensor transmitter can be connected to various single and multi-channel ENMET controllers or computer-based instrumentation, such as PLCs, SCADAs, BMSs, etc.
- Infrared sensor
- Three alarm LEDs
- 24 VDC, 4-20 mA
- NEMA 4X, NEMA 7 and IP66 rated enclosure
- Immune to poisoning
- Operates in anaerobic atmospheres and in continuous hydrocarbon environments
- Minimal maintenance and long-term stability
- Liquid crystal display
- Non-intrusive calibration
- Designed for Class I, Division 1, Groups B, C, & D
Display: Backlit LCD
Alarm Indicators: 3 LEDs at programmable set points
Sensor Type: Infrared (IR)
Menu/Calibration: Magnet-actuated switches
Voltage: 24 VDC powered
Output: 4-20 mA
Installation: 3-wire
Connection: 1/2 inch NPT, conduit
Humidity Range: 0-95%rH, non-condensing
Temperature Range: -4 to +122°F (-20 to +50°C)
Weight: 5.5 lbs (2.5 Kg)
Approval & Certifications*
Enclosure:
Class I, Groups B, C, D
Class II, Groups E, F, G
CanElec: EEx d IIC, IP66
IR Sensor:
ATEX certifications:
I M2 EExd l
II 2 G EEx d IIC
Certifications:
FM Standard 3615
CSA Standard C22.2 No. 30
UL Standard 1203
CENELEC EN 50014, 50018
IECEx certifications:
Ex d l and/or Ex d IIC
UL Recognized:
Class I, Groups A, B, C, D
T4 with 60°C ambient.
*Approvals and certifications apply to the sensor and enclosure as individual components, not for the combined unit.
EXAMPLES of Some Typical Calibrations
Gas/Vapor Range: % Vol. Range: % LEL
Methane, CH4 0-5.0 0-100
Methane, CH4 0-100 —
Propane, C3H8 0-2.1 0-100
Propane, C3H8 0-100 —
Propylene, C3H6 0-2.0 0-100
Butane, C4H10 0-1.6 0-100
Pentane, C5H12 0-1.5 0-100
Ethane, C2H6 0-3.0 0-100
Some other calibrations (% by volume) available:
Ethylene 0-3%
Isopropanol 0-2%
Hexane 0-1%
Methanol 0-5.5%
Ethanol 0-5%
ETO 0-3%
Toluene 0-1.1%
Methyl bromide (CH3Br) 0-25000 ppm
- Butane (C4H10)
- Combustible Gas
- Ethane (C2H6)
- Ethanol (CH3CH2OH)
- Ethyl alcohol (C2H5OH)
- Ethylene (C2H4)
- Ethylene oxide (ETO) (C2H4O)
- Hexane (C6H14)
- Hydrocarbons
- Isopropanol (CH3) CHOH
- Isopropyl alcohol (IPA) (C3H8O)
- Methane (CH4)
- Methanol (CH3OH)
- Methyl alcohol (CH3OH)
- Natural Gas
- Pentane (C5H12)
- Propane (C3H8)
- Propylene (C3H6)
- Toluene (C7H8)
Calibration Equipment/Replacement Parts/Accessories for EX-5120:
Part No. Description
03700-034 Sampling/Calibration Adapter for EX-5120 Sensor/Transmitters
02506-004 Gas Regulator Assembly for 34 liter steel gas cylinders
04546-004 Splash Guard for EX-5120
50030-001 Replacement Magnet
To place an order, please contact our experienced and professional customer service team:
PHONE: 734-761-1270
EMAIL: [email protected]
If you cannot find what you need or require a custom part, simply call and speak to one of our knowledgeable gas monitoring experts. They will be able to walk you through the ordering process quickly and professionally.
Description Part No.
EX-5120 Sensor/Transmitter supplied with magnet and instruction manual 10014-003