EX-5130 Electrochemical Reactive Gases Sensor
Sensor/Transmitter for Reactive Gases in Hazardous Locations
The EX-5130 Series Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier. To enable the reactive gases to reach the sensor, the normal sintered metal disk is removed from in front of the sensor. The sensor is connected to an internal intrinsic safety barrier. Gas molecules enter the cell and, as a result of an oxidation/reduction reaction, generate an electrical current proportional to the gas concentration. This current is measured, conditioned, converted to the gas concentration, digitally displayed and transmitted as a 4-20 mA output signal. ENMET offers venturi-type gas samplers and a variety of multi-channel controller/alarm modules that provide the 24 VDC loop power and receive the 4-20 mA signal from the sensor/transmitters. These systems can also be connected to various computer-based instrumentation, PLCs, etc.
- Electrochemical sensor
- Three Alarm LEDs
- 24 VDC, 4-20 mA
- NEMA 4X, NEMA 7 and IP66 rated enclosure
- liquid crystal display
- Non-intrusive calibration
- Designed for Class I, Division 1, Groups B, C, & D
Display: Backlit LCD
Alarm Indicators: 3 LEDs at programmable set points
Sensor Type: Electrochemical cell
Menu/Calibration: Magnet-actuated switches
Voltage: 24 VDC powered
Output: 4-20 mA
Installation: 3-wire
Connection: 1/2 inch NPT, conduit
Humidity Range: 0-95%rH, non-condensing
Temperature Range: -4 to +122°F (-20 to +50°C)
Weight: 5.5 lbs (2.5 Kg)
Design: Transmitter enclosure is approved for Class I, Div. 1, Groups B, C, & D
The electrochemical sensor is connected to an internal intrinsic safety barrier.
THE EX-5130* IS AVAILABLE FOR:
Gas Range
Arsine, AsH3 0.50 ppm
Bromine, Br2 10.0 ppm
Chlorine, Cl2 10.0 ppm
Ethylene oxide, ETO 10.0 ppm
Hydrogen bromide, HBr 30.0 ppm
Hydrogen chloride, HCl 30.0 ppm
Hydrogen fluoride, HF 10.0 ppm
Ozone, O3 1.00 ppm
*NOTE: It is recommended that a gas sampler be used with the EX-5130 sensor/transmitter for detecting these gases.
- Arsine (AsH3)
- Bromine (Br2)
- Chlorine (Cl2)
- Chlorine dioxide (CLO2)
- Ethylene oxide (ETO) (C2H4O)
- Hydrogen bromide (HBr)
- Hydrogen chloride (HCl)
- Hydrogen cyanide (HCN)
- Hydrogen fluoride (HF)
- Ozone (O3)
- Silane (SiH4)
Calibration Equipment/Replacement Parts/Accessories for EX-5130:
Part No. Description
03700-034 Sampling/Calibration Adapter for EX-5130 Sensor/Transmitters
02506-002 Gas Regulator Assembly for 34 liter aluminum gas cylinders
04546-007 Splash Guard for EX-5130
50030-001 Replacement Magnet
To place an order, please contact our experienced and professional customer service team:
PHONE: 800-521-2978
EMAIL: [email protected]
If you cannot find what you need or require a custom part, simply call and speak to one of our knowledgeable gas monitoring experts. They will be able to walk you through the ordering process quickly and professionally.
Sensor/Transmitter supplied with magnet and instruction manual
Description Part No.
EX-5130 Sensor/Transmitter, AsH3 10013-4001
EX-5130 Sensor/Transmitter, Br2 10013-0100
EX-5130 Sensor/Transmitter, Cl2 10013-0100
EX-5130 Sensor/Transmitter, ETO 10013-5200
EX-5130 Sensor/Transmitter, HBr 10013-0400
EX-5130 Sensor/Transmitter, HCl 10013-0400
EX-5130 Sensor/Transmitter, HF 10013-0700
EX-5130 Sensor/Transmitter, O3 10013-0800
NOTE: Gas samplers— contact ENMET