EX-5150 MOS (Metal Oxide Semiconductor) Hydrocarbon Detection

Sensor/Transmitter for % LEL or PPM Hydrocarbons and Organic Solvents

The EX-5150-MOS utilizes an MOS sensor. These sensors are broad range in their response characteristics. Different types of MOS sensors are available which can be optimized for a particular gas, but they are inherently non-specific.

The MOS sensor can provide monitoring capability similar to that of the classic catalytic bead or hot-wire sensor, but it can be calibrated for either % LEL or ppm detection levels of a wide range of hydrocarbons and organic solvents. The MOS sensor can also be used for detecting certain common inorganic toxic gases, including Ammonia (NH3), Carbon monoxide (CO), Hydrogen sulfide (H2S), etc.

MOS sensors operate at lower temperatures than catalytic bead/hot-wire sensors, which makes them less prone to poisoning. The MOS sensor is therefore the sensor of choice in applications where, for example, lead, phosphates or sulfur-containing compounds are present.

  • Solid-stateMOS sensor
  • Three alarm LEDs
  • 24 VDC, 4-20 mA
  • NEMA 4X, NEMA 7 and IP66 rated enclosure
  • Poison resistant
  • Liquid crystal display
  • Non-intrusive calibration
  • Explosion-proof design

Display: Backlit LCD

Alarm Indicators: 3 LEDs at programmable set points

Sensor Type: Metal oxide semiconductor (MOS)

Menu/Calibration: Magnet-actuated switches

Voltage: 24 VDC powered

Output: 4-20 mA

Installation: 3-wire

Connection: 1/2 inch NPT, conduit.

Weight: 5.5 lbs (2.5 Kg)

Examples of Some Typical Calibrations

                      TOXIC                                                         COMBUSTIBLE               

Gas/Vapor                   Range                       Gas/Vapor                      Range

Acetone                       2000 ppm                    Acetone                           50% LEL

Ammonia                       300 ppm                    Isopropyl alcohol           50% LEL

Methyl alcohol              400 ppm                    Propane                           50% LEL

Methyl chloride             200 ppm                    Butane                             50% LEL

Toluene                          400 ppm                     Toluene                           50% LEL

MEK                               400 ppm                     Gasoline                          50% LEL

Styrene                           200 ppm                     Styrene                            50% LEL

Methylene chloride      200 ppm                      Methane                         50% LEL

Xylene                            400 ppm                      Xylene                             50% LEL

In general, the EX-5150-MOS can be calibrated for Combustible Hydrocarbons, Halogenated Hydrocarbons, Jet Fuels, Refrigerants,

Organic Solvents, Esters, Ethers, Alcohols, Ketones, some common inorganic compounds, such as, CO, H2S, and certain

other compounds and mixtures.

  • Acetone (CH3)2CO
  • Acetonitrile (CH3CN)
  • Ammonia (NH3)
  • Benzene (C6H6)
  • 1-3 Butadiene (C4H6)
  • 2-Butanone (MEK) (C4H80)
  • Cyclohexanol (CH2)5CHOH
  • Cyclohexanone
  • (CH2)5CO
  • Ethyl alcohol (C2H5OH)
  • Ethylene (C2H4)
  • Ethylene oxide (ETO) (C2H4O)
  • Freon-134
  • Gasoline
  • Heptane (C7H16)
  • Hexane (C6H14)
  • Hydrocarbons
  • Hydrogen (H2)
  • Hydrogen sulfide (H2S)
  • Isobutylene (C4H8)
  • Isopropanol (CH3) CHOH
  • Isopropyl alcohol (IPA) (C3H8O)
  • Kerosene
  • Methane (CH4)  
  • Methyl alcohol (CH3OH)
  • Methyl chloride (CH3Cl)
  • Methyl ethyl ketone (MEK) (C4H8O)
  • Methylene chloride (CH2Cl2)
  • Natural Gas
  • Organic solvents
  • Pentane (C5H12)
  • Propane (C3H8)
  • Solvents
  • Styrene (C8H8)
  • Toluene (C7H8)
  • Trichloroethylene (C2HCl3)
  • Volatile Organic Compounds (VOCs)
  • Xylene (C8H10)

Calibration Equipment/Replacement Parts/Accessories for EX-5150-MOS:

Part No.                 Description

03045-000            Sampling Adapter for EX-5150-MOS

03700-001            Complete Assembly includes Calibration Adapter, Humidifier & Regulator for 34 liter steel gas cylinders (for gases other than Toluene & Ammonia)

03700-009            Complete Assembly includes Calibration Adapter, Humidifier & Regulator for 34 liter aluminum gas cylinder, Toluene (see P/N 03386-100 below)

03386-100            Calibration Gas, 34 liter aluminum cylinder, 100 ppm Toluene, C7H8

03700-005            Complete Assembly includes Calibration Adapter, Humidifier & Regulator for 58 liter aluminum gas cylinder Ammonia (see P/N 03230-300 below)

03230-300            Calibration Gas, 58 liter aluminum cylinder, 300 ppm (200 ppm result) Ammonia, NH3

04546-006            Splash Guard for EX-5150 MOS

50030-001            Replacement Magnet

To place an order, please contact our experienced and professional customer service team:

PHONE: 734-761-1270

If you cannot find what you need or require a custom part, simply call and speak to one of our knowledgeable gas monitoring experts. They will be able to walk you through the ordering process quickly and professionally.

Description                                                                                                                                 Part No.

EX-5150-MOS Sensor/Transmitter supplied with magnet and instruction manual       10014-008