EX-5175 Electrochemical H2, O2, H2S & Other Toxic Gases Sensor
Explosion-proof Remote Gas Monitoring Sensor Transmitter for H2, O2, CO, H2S and Other Toxic Gases
EX-5175 remote gas monitoring sensor transmitter utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier. Gas molecules enter the cell and, as a result of an oxidation/reduction reaction, generate an electrical current proportional to the gas concentration. This current is measured, conditioned, converted to the gas concentration, digitally displayed and transmitted as a 4-20 mA output signal. The Ex-5175 sensor transmitter operates on 24 VDC power and features three LED alarm point indicators and 4-20 mA output. This sensor transmitter can be connected to various single and multi-channel ENMET controllers or computer-based instrumentation, such as PLCs, SCADAs, BMSs, etc.
- Electrochemical sensor
- Three alarm LEDs
- 24 VDC, 4-20 mA
- NEMA 4X, NEMA 7 and IP66 rated enclosure
- liquid crystal display
- Non-intrusive calibration
- Approved for Class I, Division 1, Groups B, C, & D
Display: Backlit LCD
Alarm Indicators: 3 LEDs at programmable set points
Sensor Type: Electrochemical cell
Menu/Calibration: Magnet-actuated switches
Voltage: 24 VDC powered
Output: 4-20 mA
Installation: 3-wire
Connection: 1/2 inch NPT, conduit
Humidity Range: 5 to 90%rH, non-condensing
Temperature Range: -4 to +104°F (-20 to +40°C)
Weight: 5.5 lbs (2.5 Kg)
Approval & Certifications:
Approvals:
Approved for Class I, Div. 1, Groups B,C, & D
Classified to:
UL 916 (3rd ed.) and UL 1203 (4th ed.)
CSA 22.2, No. 0-M91, 30-M1986 and 142-M1987
THE EX-5175 IS AVAILABLE FOR:
Gas Range
Ammonia, NH3 100 ppm
Carbon monoxide, CO 500 ppm
Hydrogen, H2 2000 ppm
Hydrogen sulfide, H2S 100 ppm
Nitric oxide, NO 100 ppm
Nitrogen dioxide, NO2 30.0 ppm
Oxygen, O2 (% by volume) 30.0 %
Sulfur dioxide, SO2 30.0 ppm
- Ammonia (NH3)
- Carbon monoxide (CO)
- Ethylene (C2H4)
- Hydrogen (H2)
- Hydrogen sulfide (H2S)
- Nitrogen dioxide (NO2)
- Oxygen (O2)
- Sulfur dioxide (SO2)
Calibration Equipment/Replacement Parts/Accessories for EX-5175:
Part No. Description
03700-034 Sensor Sampling/Calibration Adapter for EX-5175 Sensor/Transmitter
02506-002 Gas Regulator Assembly for 34 liter aluminum gas cylinders
02506-004 Gas Regulator Assembly for 34 liter steel gas cylinders
04546-004 Splash Guard for EX-5175
50030-001 Replacement Magnet
To place an order, please contact our experienced and professional customer service team:
PHONE: 734-761-1270
EMAIL: [email protected]
If you cannot find what you need or require a custom part, simply call and speak to one of our knowledgeable gas monitoring experts. They will be able to walk you through the ordering process quickly and professionally.
Sensor/Transmitter supplied with magnet and instruction manual
Description Part No.
EX-5175 Sensor/Transmitter, H2S 10014-0200
EX-5175 Sensor/Transmitter, SO2 10014-0500
EX-5175 Sensor/Transmitter, O2 10014-1100
EX-5175 Sensor/Transmitter, CO 10014-1200
EX-5175 Sensor/Transmitter, H2, 0-2000 ppm 10014-1500
EX-5175 Sensor/Transmitter, H2, 0-9999 ppm 10014-1503
EX-5175 Sensor/Transmitter, NO2 10014-1700
EX-5175 Sensor/Transmitter, NO 10014-1750
EX-5175 Sensor/Transmitter, NH3 10014-2400